Part Number Hot Search : 
95200 C6VDC MUR7010 MC1403 BLF6G 6M181RPA 7461116 1A08AV
Product Description
Full Text Search
 

To Download AKD4104-A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 [AKD4104-A]
AKD4104-A
AK4104 Evaluation Board Rev.0
GENERAL DESCRIPTION The AKD4104-A is an evaluation board for the AK4104, 192 kHz 24-Bit 3.3V DIT. The AKD4104-A be designed for getting digital interface signals from extern instruments, it is easy to evaluate the AK4104. Ordering guide
AKD4104-A --AK4104 Evaluation Board
FUNCTION
* Get digital interface signals form extern instruments using PORT3 (DSP) * Optical output for internal DIT
DGND
VCC
VDD AGND
74LVC541 10pin Header DSP Data
AK4104
Digital Out OPT
Figure 1. AKD4104-A Block Diagram
-1-
2007/05
[AKD4104-A]
Operation sequence
1) Set up the power supply lines. [VDD] (Red) = 2.7 3.6V (typ. 3.3V, for AK4104) [VCC] (Red) = 2.7 3.6V (typ. 3.3V, for 74LVC541 and for logic) [AGND] (Black) = 0V [DGND] (Black) = 0V Each supply line should be distributed from the power supply unit. 2) Set-up the evaluation modes, jumper pins (See the followings.) 3) Power on. AK4104 should be reset once by bringing SW1 "L" upon power-down. AK4104 can power-up when bringing SW1 "H".
Evaluation mode
D/D part evaluation using PORT3 (DSP), and supplying all interface signals from external equipments In case of using PORT3 (DSP), and supplying signals (MCLK, BICK, LRCK, SDTI) that is needed for the AK4104 from external equipments, set up jumper pins as following. JP2 (CDTO / SDTI2) : CDTO / SDTI2 pins CDTO: CDTO be selected SDTI2: SDTI2 be selected JP3 (SDTI2) : TEST1 pin VDD: shorted with GND GND: shorted with GND JP15 (VDD) : VDD and VCC can be shorted OPEN: Separate VDD and VCC SHORT: Short VDD and VCC JP16 (GND) : AGND and DGND can be shorted OPEN: Separate AGND and DGND SHORT: Short AGND and DGND
-2-
2007/05
[AKD4104-A]
The function of the toggle SW
[SW1] (AK4104-PDN): Resets the AK4104. Keep "H" during normal operation. The AK4104 should be reset once by bringing SW1 "L" upon power-up.
Serial control
The AKD4104-A can be controlled via the printer port (parallel port) of IBM-AT compatible PC. Connect PORT4 (uP-I/F) to PC by 10-line flat cable packed with the AKD4104-A. Take care of the direction of connector. There is a mark at pin#1. The pin layout of PORT4 as shown Figure 3.
PORT4 uP I/F 9 CDTO
CCLK
CDTI
CSN
NC
1
GND
GND
GND
10
Figure 3. PORT4 pin layout
-3-
GND GND
2
2007/05
[AKD4104-A]
Control Software Manual Set-up of evaluation board and control software
1. Set up the AKD4104-A according to the Operating Sequence located on page 2. 2. Connect IBM-AT compatible PC with AKD4104-A by 10-line type flat cable (packed with AKD4104-A). Take care of the direction of 10pin header. (Please install the driver in the CD-ROM when this control software is used on Windows 2000/XP. Please refer "Installation Manual of Control Software Driver by AKM device control software". In case of Windows95/98/ME, this installation is not needed. This control software does not operate on Windows NT.) 3. Insert the CD-ROM labeled "AKD4104-A Evaluation Kit" into the CD-ROM drive. 4. Access the CD-ROM drive and double-click the icon of "AKD4104-A.exe" to set up the control program. 5. Please evaluate according to the following.
Operation flow
Keep the following flow. 1. Set up the control program according to explanation above. 2. Click "Port Reset" button.
Explanation of each buttons
1. [Port Reset]: 2. [Write default]: 3. [All Write]: 4. [Function1]: 5. [Function2]: 6. [Function3]: 7. [Function4]: 8. [Function5]: 9. [SAVE]: 10. [OPEN]: 11. [Write]: Set up the USB interface board (AKDUSBIF-A) . Initialize the register of AK4104. Write all registers that is currently displayed. Dialog to write data by keyboard operation. Dialog to write data by keyboard operation. The sequence of register setting can be set and executed. The sequence that is created on [Function3] can be assigned to buttons and executed. The register setting that is created by [SAVE] function on main window can be assigned to buttons and executed. Save the current register setting. Write the saved values to all register. Dialog to write data by mouse operation.
Indication of data
Input data is indicated on the register map. Red letter indicates "H" or "1" and blue one indicates "L" or "0". Blank is the part that is not defined in the datasheet.
-4-
2007/05
[AKD4104-A]
Explanation of each dialog 1. [Write Dialog]: Dialog to write data by mouse operation
There are dialogs corresponding to each register. Click the [Write] button corresponding to each register to set up the dialog. If you check the check box, data becomes "H" or "1". If not, "L" or "0". If you want to write the input data to AK4104, click [OK] button. If not, click [Cancel] button.
2. [Function1 Dialog] : Dialog to write data by keyboard operation
Address Box: Input registers address in 2 figures of hexadecimal. Data Box: Input registers data in 2 figures of hexadecimal. If you want to write the input data to AK4104, click [OK] button. If not, click [Cancel] button.
3. [Function2 Dialog] : Dialog to evaluate ATT
Address Box: Start Data Box: End Data Box: Interval Box: Step Box: Input registers address in 2 figures of hexadecimal. Input starts data in 2 figures of hexadecimal. Input end data in 2 figures of hexadecimal. Data is written to AK4104 by this interval. Data changes by this step.
Mode Select Box: *If you check this check box, data reaches end data, and returns to start data. [Example] Start Data = 00, End Data = 09 Data flow: 00 01 02 03 04 05 06 07 08 09 09 08 07 06 05 04 03 02 01 00 *If you do not check this check box, data reaches end data, but does not return to start data. [Example] Start Data = 00, End Data = 09 Data flow: 00 01 02 03 04 05 06 07 08 09 If you want to write the input data to AK4104, click [OK] button. If not, click [Cancel] button.
-5-
2007/05
[AKD4104-A]
4. [Save] and [Open] 4-1. [Save]
Save the current register setting data. The extension of file name is "akr".
(Operation flow)
(1) Click [Save] Button. (2) Set the file name and push [Save] Button. The extension of file name is "akr". 4-2. [Open] The register setting data saved by [Save] is written to AK4104. The file type is the same as [Save].
(Operation flow)
(1) Click [Open] Button. (2) Select the file (*.akr) and Click [Open] Button.
-6-
2007/05
[AKD4104-A]
5. [Function3 Dialog]
The sequence of register setting can be set and executed. (1) Click [F3] Button. (2) Set the control sequence. Set the address, Data and Interval time. Set "-1" to the address of the step where the sequence should be paused. (3) Click [Start] button. Then this sequence is executed. The sequence is paused at the step of Interval="-1". Click [START] button, the sequence restarts from the paused step. This sequence can be saved and opened by [Save] and [Open] button on the Function3 window. The extension of file name is "aks".
Figure 4. Window of [F3]
-7-
2007/05
[AKD4104-A]
6. [Function4 Dialog]
The sequence that is created on [Function3] can be assigned to buttons and executed. When [F4] button is clicked, the
window as shown in Figure5 opens.
Figure 5. [F4] window
-8-
2007/05
[AKD4104-A]
6-1. [OPEN] buttons on left side and [START] buttons
(1) Click [OPEN] button and select the sequence file (*.aks). The sequence file name is displayed as shown in Figure6.
Figure 6. [F4] window(2) (2) Click [START] button, then the sequence is executed.
6-2. [SAVE] and [OPEN] buttons on right side
[SAVE]: The sequence file names can assign be saved. The file name is *.ak4. [OPEN]: The sequence file names assign that are saved in *.ak4 are loaded.
6-3. Note
(1) This function doesn't support the pause function of sequence function. (2) All files need to be in same folder used by [SAVE] and [OPEN] function on right side. (3) When the sequence is changed in [Function3], the file should be loaded again in order to reflect the change.
-9-
2007/05
[AKD4104-A]
7. [Function5 Dialog] The register setting that is created by [SAVE] function on main window can be assigned to buttons and executed. When [F5] button is clicked, the following window as shown in Figure7 opens.
Figure 7. [F5] window
7-1. [OPEN] buttons on left side and [WRITE] button
(1) Click [OPEN] button and select the register setting file (*.akr).
(2) Click [WRITE] button, then the register setting is executed.
7-2. [SAVE] and [OPEN] buttons on right side
[SAVE] : The register setting file names assign can be saved. The file name is *.ak5. [OPEN] : The register setting file names assign that are saved in *.ak5 are loaded.
7-3. Note
(1) All files need to be in same folder used by [SAVE] and [OPEN] function on right side. (3) When the register setting is changed by [Save] Button in main window, the file should be loaded again in order to reflect the change.
- 10 -
2007/05
[AKD4104-A]
Revision History Date (yy/mm/dd) 07/07/05 Manual Revision KM089600 Board Revision 0 Reason First Edition Contents
IMPORTANT NOTICE These products and their specifications are subject to change without notice. When you consider any use or application of these products, please make inquiries the sales office of Asahi Kasei EMD Corporation (AKEMD) or authorized distributors as to current status of the products. AKEMD assumes no liability for infringement of any patent, intellectual property, or other rights in the application or use of any information contained herein. Any export of these products, or devices or systems containing them, may require an export license or other official approval under the law and regulations of the country of export pertaining to customs and tariffs, currency exchange, or strategic materials. AKEMD products are neither intended nor authorized for use as critical componentsNote1) in any safety, life support, or other hazard related device or systemNote2), and AKEMD assumes no responsibility for such use, except for the use approved with the express written consent by Representative Director of AKEMD. As used here: Note1) A critical component is one whose failure to function or perform may reasonably be expected to result, whether directly or indirectly, in the loss of the safety or effectiveness of the device or system containing it, and which must therefore meet very high standards of performance and reliability. Note2) A hazard related device or system is one designed or intended for life support or maintenance of safety or for applications in medicine, aerospace, nuclear energy, or other fields, in which its failure to function or perform may reasonably be expected to result in loss of life or in significant injury or damage to person or property. It is the responsibility of the buyer or distributor of AKEMD products, who distributes, disposes of, or otherwise places the product with a third party, to notify such third party in advance of the above content and conditions, and the buyer or distributor agrees to assume any and all responsibility and liability for and hold AKEMD harmless from any and all claims arising from the use of said product in the absence of such notification.
- 11 -
2007/05
A
B
C
D
E
E
E
CN1
U1
CN2
AK4104-MCLK
D
1
1
MCLK
TX
16
16
AK4104-TX AK4104-CDTO AK4104-SDTI2 VDD
D
AK4104-BICK AK4104-SDTI1 AK4104-LRCK AK4104-PDN
2
2
BICK
CDTO/SDTI2
15
JP2(3x1) CDTO/SDTI2
15
3
3
SDTI1
VDD
14
4
4
LRCK
VSS
13
C1 0.1u
+
14
C2 10u
13
5
5
PDN
TEST4
12
12
C
AK4104-CSN AK4104-CCLK AK4104-CDTI
6
6
CSN
TEST3
11
11
C
7
7
CCLK
TEST2
10
10
8
8
CDTI
TEST1
9
9
AK4104
B B
A
A
Title
Size
A
B
C
Date:
D
AKD4104-A A4 AK4104 Tuesday, July 03, 2007
Document Number Sheet
E
Rev
2
of
1
6
A
B
C
D
E
E
E
VCC U3
1
G1
VCC
20
19
G2
GND
10
C12 0.1u R2 R3 R4 R5 51 AK4104-MCLK 51 AK4104-BICK 51 AK4104-SDTI1 51 AK4104-LRCK AK4104-PDN AK4104-SDTI2
C
D
PORT3-MCLK PORT3-BICK PORT3-SDTI1 PORT3-LRCK
2
A1
Y1
18
D
3
A2
Y2
17
4
A3
Y3
16
5
A4
Y4
15
C
74LVC541A-PDN PORT3-SDTI2 PORT3 GND JP8 (3x1) SDTI2
6
A5
Y5
14
7
A6
Y6
13
8
A7
Y7
12
9
A8
Y8
11
B
74LVC541A
B
A
A
Title Size Document Number
A4
A B C
AKD4104-A 74LVC541A
Sheet
E
Rev
2
of
Date:
D
Tuesday, July 03, 2007
3
6
A
B
C
D
E
VCC
E
PORT3-MCLK PORT3-BICK D1 HSU119 R8 10k U8A
1 2 3
E
PORT3-LRCK U8B
4
K
A
PORT3-SDTI1 74LVC541A-PDN PORT3-SDTI2 PORT3 A1-10PA-2.54DSA MCLK 1 10 BICK 2 9 LRCK 3 8 SDTI1 4 7 SDTI2 5 6 DSP
D
L
3
H
1
74HC14 C15 0.1u
74HC14
SW1 ATE1D-2M3
D
AK4104-PDN
2
3
4
U9B 74HCT04 U9C 74HCT04 U9D 74HCT04 U9E 74HCT04
11
U8E
10
VCC VCC R19 R22 R25 10k 10k 10k R20 R23 R26 470 470 470
2 3 5 6 11 10 14 13 1 15 1A 1B 2A 2B 3A 3B 4A 4B A/B G
74HC14
14
5
C
6
VCC U8F
12
U10 74HCT157
1Y 2Y 3Y 4Y 4 7 9 12
16
VCC
13 7
R21 R24 R27 R28 R29 100K
100 100 100 100
AK4104-CSN AK4104-CCLK AK4104-CDTI AK4104-CDTO
C
9
8
74HC14
11
10
VCC U9F 74HCT04
14
13
B
12 7
PORT4 A1-10PA-2.54DSA 10 9 CSN 8 7 CCLK 6 5 CDTI 4 3 CDTO
2 1
uP-I/F
R30
(short)
8
GND
B
PORT2 TOTX141 TX(OPT)
IN VCC GND
3 2 1
VCC C18 0.1u
AK4104-TX
A
A
Title Size
AKD4104-A
Document Number Rev
A4
A B C
Date:
D
Input Output for Digital Analog Sheet
Tuesday, July 03, 2007
E
2
5
of
6
A
B
C
D
E
E
VDD T_45(RED)
VCC T_45(RED)
AGND DGND T_45(BLACK)T_45(BLACK)
E
1
1
1
VDDi
VCCi
AGND
DGND
VDDi
1
D
VCCi
1
1
L2 (short)
2
L3 (short) JP15 (2x1) R31 (short) C22 open R32 (short) JP16 AGND (2x1) DGND GND C23 open C24 open C25 open C26 0.1u C27 0.1u C28 0.1u For 74HC14 x 1, 74HCT04 x 1, 74AC74 x 1, 74HC4040 x 1, 74AC163 x 1, 74HC14 x 1
2
D
VCC
C20 47u +
VDD C21 47u +
C
VDD
C
B
B
A
A
Title Size Document Number
A4
A B C
AKD4104-A Power Supply
Sheet
E
Rev
2
of
Date:
D
Tuesday, July 03, 2007
6
6


▲Up To Search▲   

 
Price & Availability of AKD4104-A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X